Product Archive
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Model | AC099RSYS | AC127RSYS |
| Indoor unit | AY-X099J | AY-A127J |
| Outdoor unit | AE-X099J | AE-A127J |
| Inverter variable output cooling (KW) | 2.5* (0.9~2.8)+ | 3.4* (1.4~3.8)+ |
|
BTU/h |
8,532 (3,072~9,556) | 11,604 (4,778~12,969) |
| Inverter variable output heating (KW) | 3.3* (0.9~3.9)+ | 4.5* (1.4~5.7)+ |
|
BTU/h |
11,263(3,072~13,311) | 15,359(4,778~19,454) |
| Co-efficient of performance cooling | 2.12 | 1.98 |
| Co-efficient of performance heating | 2.54 | 2.53 |
| 24 hour timer | Y | Y |
| 1 hour timer | Y | Y |
| Anti mould filter | Y | Y |
| Cleanable filter | Y | Y |
| Sleep mode | Y | Y |
| Auto swing louvers | Y | Y |
| LCD remote | Y | Y |
| Power save mode | Y | Y |
| Operating modes | 5 | 5 |
| Fan speeds | 3 + auto | 3 + auto |
| Maximum pipe length | 15 | 15 |
| Indoor sound pressure db(A) | 28/32/36 | 33/37/41 |
| Outdoor sound pressure db(A) | 61 | 67 |
| Voltage | 230-240 | 230-240 |
| Frequency Hz | 50 | 50 |
| Maximum rated current (A) | 6.3 | 11.3 |
|
Dimension HxWxD mm indoor |
270x750x185 | 270x790x188 |
|
outdoor |
530x698x250 | 530x728x250 |
| Weight | 7 kg indoor 30 kg outdoor |
7 kg indoor 49 kg outdoor |
| Compressor type | Rotary (inverter) | Rotary (inverter) |
| Warranty applies to products sold in Australia. Design and specification are current as of June 2001, but are subject to change without prior notice. The manufacturer reserves the right to vary specification, design or use of the alternative materials as may be deemed necessary or desirable at any time, any such change or variation being of a kind as not to reduce the quality, performance or appearance. +Output capacity denoted with an * is the inverter units rated capacity when tested under conditions A set by the Australian Standard AS1861.1 (1998). The output capacity range denoted in brackets indicates the the minimum & maximum output capacity of the inverter unit. Minimum output capacity is the Inverter unit's capacity when it switches to low power operation to provide "Even Temperature Control". Maximum output capacity is only for the first hour of operation when the "Boost" function is used. These rating should not be used to determine the power requirements for the room. Due to the superior technology employed in inverter air-conditioner, the current star rating is under review. The high efficiency is not reflected accurately under the current test conditions |